Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 199
Filter
3.
J Cardiol ; 83(3): 184-190, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37684005

ABSTRACT

BACKGROUND: As the catheter-based device closure of the patent foramen ovale (PFO) is expanding, novel devices aim to address the limitations of first-generation occluders (e.g. bulk, erosion, dislodgment). The second-generation device from Encore Medical (Eagan, MN, USA) features an articulating frame structure which allows the device to better conform to atrial anatomies, has lower disc thickness and metal mass/surface area, and is fully retrievable at any point in the procedure. The aim of the study was to evaluate the feasibility and safety of a novel low-profile, fully retrievable, Encore PFO closure device in the animal model. METHODS: Six swine underwent implantation of the novel PFO occluder under fluoroscopic and intra-cardiac echocardiography guidance and survived for 140 days. Interim transthoracic echocardiography (TTE) was conducted on Day 29. Following terminal angiography and TTE at 140 days, the hearts were subjected to gross and histopathologic analysis. RESULTS: All animals were successfully implanted and survived for 140 days. Interim TTE revealed proper device retention with no blood flow across the septum or thrombus in any of the animals. X-ray and pathology results showed preserved implant integrity with no fractures, and complete integration of the devices into the septum with complete re-endothelialization and nearly complete coverage by a mature, relatively thin neoendocardium. No surface fibrin deposition or thrombosis was reported. CONCLUSIONS: In the standard porcine model, device retention and biocompatibility remained favorable following structural and functional device modifications exemplified by the second-generation PFO occluder from Encore Medical, including marked reduction of metal mass.


Subject(s)
Foramen Ovale, Patent , Septal Occluder Device , Swine , Animals , Treatment Outcome , Cardiac Catheterization/methods , Echocardiography , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Fluoroscopy
4.
Front Cardiovasc Med ; 10: 1180299, 2023.
Article in English | MEDLINE | ID: mdl-38045907

ABSTRACT

New generation 3-dimensional matrix array intracardiac echocardiography catheters have become commercially available recently, increasing image plane options compared to 2-dimensional and older generation 3-dimensional intracardiac echocardiography catheters. They are beginning to play an important role in structural heart interventions, especially for transcatheter tricuspid interventions, due to advantages in some situations that increase image quality over transesophageal echocardiography.

5.
Article in English | MEDLINE | ID: mdl-38060997

ABSTRACT

AIMS: The conceptual framework of proportionate versus disproportionate mitral regurgitation (MR) translates poorly to individual patients with heart failure (HF) and secondary MR. A novel index, the ratio of MR severity to left atrial volume (LAV), may identify patients with "disproportionate" MR and a higher risk of events. The objectives, therefore, were to investigate the prognostic impact of MR severity to LAV ratio on outcomes among HF patients with severe secondary MR randomized to transcatheter edge-to-edge repair (TEER) with the MitraClipTM device plus guideline-directed medical therapy (GDMT) vs. GDMT alone in the COAPT trial. METHODS AND RESULTS: The ratio of preprocedural regurgitant volume (RVol) to LAV was calculated from baseline transthoracic echocardiograms. The primary endpoint was 2-year covariate-adjusted rate of HF hospitalization (HFH).Among 567 patients, the median RVol/LAV was 0.67 (IQR 0.48-0.91). In patients randomized to GDMT alone, lower RVol/LAV was independently associated with an increased 2-year risk of HFH (adjHR: 1.77; 95% CI: 1.20-2.63). RVol/LAV was a stronger predictor of adverse outcomes than RVol or LAV alone. Treatment with TEER plus GDMT compared with GDMT alone was associated with lower 2-year rates of HFH both in patients with low and high RVol/LAV (Pinteraction = 0.28). Baseline RVol/LAV ratio was unrelated to 2-year mortality, health status, or functional capacity in either treatment group. CONCLUSIONS: Low RVol/LAV ratio was an independent predictor of 2-year HFH in HF patients with severe MR treated with GDMT alone in the COAPT trial. TEER improved outcomes regardless of baseline RVol/LAV ratio. CLINICAL TRIAL REGISTRATION: Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL: https://clinicaltrials.gov/ct2/show/NCT01626079.

7.
Atheroscler Plus ; 54: 30-41, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38116576

ABSTRACT

Background and aim: The complex dynamic interplay between different biological pathways involved in atherosclerosis development has rendered the identification of specific therapeutic targets a challenging quest. We aimed to identify specific genes and mechanistic pathways associated with the early development of fibro-atheromas in a swine model of atherosclerosis. Methods: The Wisconsin Miniature Swine™ model of Familial Hypercholesterolemia (WMS-FH, n = 11) and genetically related WMS controls (WMS-N, n = 11) were used. The infrarenal aorta was harvested from both groups for histopathologic and transcriptomic profiling at 12 months. Bioinformatic analysis was performed to identify hub genes and pathways central to disease pathophysiology. The expression of ITGB2, the top ranked hub gene, was manipulated in cell culture and the expression of interconnected genes was tested. Results: Fibro-atheromatous lesions were documented in all WMS-FH aortic tissues and displayed internal elastic lamina (IEL) disruption, significant reduction of myofibroblast presence and disorganized collagen deposition. No fibro-atheromas were observed in the control group. A total of 266 differentially expressed genes (DEGs) were upregulated in WMS-FH aortic tissues, while 29 genes were downregulated. Top identified hub genes included ITGB2, C1QA, LCP2, SPI1, CSF1R, C5AR1, CTSS, MPEG1, C1QC, and CSF2RB. Overexpression of ITGB2 resulted in elevated expression of other interconnected genes expressed in porcine endothelial cells. Conclusion: In a swine translational model of atherosclerosis, transcriptomic analysis identified ITGB2 as a central hub gene associated inflammation and early fibroatheroma development making it a potential therapeutic target at this stage of disease.

8.
Sci Rep ; 13(1): 19355, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37935844

ABSTRACT

Atherosclerosis is a complex progressive disease involving intertwined biological mechanisms. We aimed to identify miRNA expression dynamics at the early stages of atherosclerosis using a large swine model (Wisconsin Miniature Swine, WMS). A total of 18 female pigs; 9 familial hypercholesterolemic (WMS-FH) and 9 normal control swine (WMS-N) were studied. miRNA sequencing was performed on plasma cell-free RNA at 3, 6, and 9 months of age. RT-qPCR validated DE miRNAs in a new cohort of animals (n = 30) with both sexes. Gene ontology and mRNA targets for DE miRNAs were identified. In vivo multimodality imaging and histopathology were performed to document the presence of atherosclerosis at termination. 20, 19, and 9 miRNAs were significantly DE between the groups at months 3, 6, and 9, respectively. Most DE miRNAs and their target genes are involved in human atherosclerosis development. Coronary atherosclerosis was documented in 7/9 WMS-FH pigs. Control animals had no lesions. miR-138, miR-152, miR-190a, and miR-196a showed a significant diagnostic power at month 3, whereas miR-486, miR-126-3p, miR-335, and miR-423-5p were of significant diagnostic power at month 9. In conclusion, specific DE miRNAs with significant discriminatory power may be promising biomarkers for the early detection of coronary atherosclerosis.


Subject(s)
Atherosclerosis , Circulating MicroRNA , Coronary Artery Disease , Hyperlipoproteinemia Type II , MicroRNAs , Humans , Male , Female , Swine , Animals , Coronary Artery Disease/genetics , MicroRNAs/metabolism , Atherosclerosis/genetics , Atherosclerosis/pathology , Biomarkers , Hyperlipoproteinemia Type II/genetics , Circulating MicroRNA/genetics , Swine, Miniature/genetics , Swine, Miniature/metabolism
9.
JACC Case Rep ; 22: 101986, 2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37790763

ABSTRACT

A 65-year-old obese woman with rheumatic heart disease and restrictive lung disease presented with decompensated heart failure. Evaluation demonstrated severely thickened mitral valve leaflets, severe mitral stenosis, and moderate mitral regurgitation. She underwent successful transfemoral transseptal transcatheter mitral valve replacement with a dedicated valve resulting in improved functional status. (Level of Difficulty: Advanced.).

10.
Ann Thorac Surg ; 2023 Sep 17.
Article in English | MEDLINE | ID: mdl-37717882

ABSTRACT

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

11.
J Am Coll Cardiol ; 82(2): 128-138, 2023 07 11.
Article in English | MEDLINE | ID: mdl-37306651

ABSTRACT

BACKGROUND: Although malnutrition is associated with poor prognosis in several diseases, its prognostic impact in patients with heart failure (HF) and secondary mitral regurgitation (SMR) is not understood. OBJECTIVES: The purpose of this study was to assess the prevalence and impact of malnutrition in HF patients with severe SMR randomized to transcatheter edge-to-edge repair (TEER) with the MitraClip plus guideline-directed medical therapy (GDMT) vs GDMT alone in the COAPT trial. METHODS: Baseline malnutrition risk was calculated using the validated geriatric nutritional risk index (GNRI) score. Patients were categorized as having "malnutrition" (GNRI ≤98) vs "no malnutrition" (GNRI >98). Outcomes were assessed through 4 years. The primary endpoint of interest was all-cause mortality. RESULTS: Among 552 patients, median baseline GNRI was 109 (IQR: 101-116); 94 (17.0%) had malnutrition. All-cause mortality at 4 years was greater in patients with vs those without malnutrition (68.3% vs 52.8%; P = 0.001). Using multivariable analysis, both baseline malnutrition (adjusted-HR [adj-HR]: 1.37; 95% CI: 1.03-1.82; P = 0.03) and randomization to TEER plus GDMT compared with GDMT alone (adj-HR: 0.65; 95% CI: 0.51-0.82; P = 0.0003) were independent predictors of 4-year mortality. In contrast, GNRI was unrelated to the 4-year rate of heart failure hospitalization (HFH), although TEER treatment reduced HFH (adj-HR: 0.46; 95% CI: 0.36-0.56). The reductions in death (adj-Pinteraction = 0.46) and HFH (adj-Pinteraction = 0.67) with TEER were consistent in patients with and without malnutrition. CONCLUSIONS: Malnutrition was present in 1 of 6 patients with HF and severe SMR enrolled in COAPT and was independently associated with increased 4-year mortality (but not HFH). TEER reduced mortality and HFH in patients with and without malnutrition. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] and COAPT CAS [COAPT]; NCT01626079).


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Aged , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Prognosis , Outcome Assessment, Health Care , Heart Failure/complications , Heart Failure/epidemiology , Heart Failure/therapy , Treatment Outcome
12.
Circ Cardiovasc Interv ; 16(6): e013045, 2023 06.
Article in English | MEDLINE | ID: mdl-37194288

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. METHODS: The CHOICE-MI registry (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) included patients with MR undergoing TMVR using dedicated devices. Patients with MR pathogeneses other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation). We compared outcomes between the TMVR and GDMT groups, using propensity score matching to adjust for baseline differences. RESULTS: After propensity score matching, 97 patient pairs undergoing TMVR (72.9±8.7 years; 60.8% men; transapical access, 91.8%) versus GDMT (73.1±11.0 years; 59.8% men) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared with 6.9% and 7.7%, respectively, in those receiving GDMT alone (both P<0.001). The 2-year rate of heart failure hospitalization was significantly lower in the TMVR group (32.8% versus 54.4%; hazard ratio, 0.59 [95% CI, 0.35-0.99]; P=0.04). Among survivors, a higher proportion of patients were in the New York Heart Association functional class I or II in the TMVR group at 1 year (78.2% versus 59.7%; P=0.03) and at 2 years (77.8% versus 53.2%; P=0.09). Two-year mortality was similar in the 2 groups (TMVR versus GDMT, 36.8% versus 40.8%; hazard ratio, 1.01 [95% CI, 0.62-1.64]; P=0.98). CONCLUSIONS: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for heart failure, and similar mortality compared with GDMT. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04688190 (CHOICE-MI) and NCT01626079 (COAPT).


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Female , Humans , Male , Cardiac Catheterization/adverse effects , Heart Failure/etiology , Heart Failure/therapy , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Propensity Score , Treatment Outcome
13.
EuroIntervention ; 19(6): 512-525, 2023 08 21.
Article in English | MEDLINE | ID: mdl-37235388

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) using dedicated devices is an alternative therapy for high-risk patients with symptomatic mitral regurgitation (MR). AIMS: This study aimed to assess the 2-year outcomes and predictors of mortality in patients undergoing TMVR from the multicentre CHOICE-MI Registry. METHODS: The CHOICE-MI Registry included consecutive patients with symptomatic MR treated with 11 different dedicated TMVR devices at 31 international centres. The investigated endpoints included mortality and heart failure hospitalisation rates, procedural complications, residual MR, and functional status. Multivariable Cox regression analysis was applied to identify independent predictors of 2-year mortality. RESULTS: A total of 400 patients, median age 76 years (interquartile range [IQR] 71, 81), 59.5% male, EuroSCORE II 6.2% (IQR 3.8, 12.0), underwent TMVR. Technical success was achieved in 95.2% of patients. MR reduction to ≤1+ was observed in 95.2% at discharge with durable results at 1 and 2 years. New York Heart Association Functional Class had improved significantly at 1 and 2 years. All-cause mortality was 9.2% at 30 days, 27.9% at 1 year and 38.1% at 2 years after TMVR. Chronic obstructive pulmonary disease, reduced glomerular filtration rate, and low serum albumin were independent predictors of 2-year mortality. Among the 30-day complications, left ventricular outflow tract obstruction, access site and bleeding complications showed the strongest impact on 2-year mortality. CONCLUSIONS: In this real-world registry of patients with symptomatic MR undergoing TMVR, treatment with TMVR was associated with a durable resolution of MR and significant functional improvement at 2 years. Two-year mortality was 38.1%. Optimised patient selection and improved access site management are mandatory to improve outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Male , Aged , Female , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/methods , Treatment Outcome , Risk Factors , Registries
15.
JACC Case Rep ; 12: 101776, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37091051

ABSTRACT

Patients with tricuspid regurgitation are often referred late in their disease course and present with volume overload, which is a detrimental factor leading to right-sided chamber dilatation and dysfunction. Treatment of volume overload can 1) improve patient functional status; 2) avoid repeated invasive examinations; and 3) establish eligibility for transcatheter tricuspid intervention. (Level of Difficulty: Intermediate.).

16.
Eur J Heart Fail ; 25(3): 399-410, 2023 03.
Article in English | MEDLINE | ID: mdl-36883620

ABSTRACT

AIMS: This study aimed to compare outcomes after transcatheter mitral valve replacement (TMVR) and mitral valve transcatheter edge-to-edge repair (M-TEER) for the treatment of secondary mitral regurgitation (SMR). METHODS AND RESULTS: The CHOICE-MI registry included 262 patients with SMR treated with TMVR between 2014 and 2022. The EuroSMR registry included 1065 patients with SMR treated with M-TEER between 2014 and 2019. Propensity score (PS) matching was performed for 12 demographic, clinical and echocardiographic parameters. Echocardiographic, functional and clinical outcomes out to 1 year were compared in the matched cohorts. After PS matching, 235 TMVR patients (75.5 years [70.0, 80.0], 60.2% male, EuroSCORE II 6.3% [interquartile range 3.8, 12.4]) were compared to 411 M-TEER patients (76.7 years [70.1, 80.5], 59.0% male, EuroSCORE II 6.7% [3.9, 12.4]). All-cause mortality was 6.8% after TMVR and 3.8% after M-TEER at 30 days (p = 0.11), and 25.8% after TMVR and 18.9% after M-TEER at 1 year (p = 0.056). No differences in mortality after 1 year were found between both groups in a 30-day landmark analysis (TMVR: 20.4%, M-TEER: 15.8%, p = 0.21). Compared to M-TEER, TMVR resulted in more effective mitral regurgitation (MR) reduction (residual MR ≤1+ at discharge for TMVR vs. M-TEER: 95.8% vs. 68.8%, p < 0.001), and superior symptomatic improvement (New York Heart Association class ≤II at 1 year: 77.8% vs. 64.3%, p = 0.015). CONCLUSION: In this PS-matched comparison between TMVR and M-TEER in patients with severe SMR, TMVR was associated with superior reduction of MR and superior symptomatic improvement. While post-procedural mortality tended to be higher after TMVR, no significant differences in mortality were found beyond 30 days.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Male , Female , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Propensity Score , Treatment Outcome , Cardiac Catheterization/methods
17.
Article in English | MEDLINE | ID: mdl-36948892

ABSTRACT

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

19.
JACC Case Rep ; 7: 101711, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36776792

ABSTRACT

We developed humanized biosimulator to predict the risk of coronary obstruction among high-risk patients undergoing valve-in-valve (ViV) procedures. In this case, based on unchanged instantaneous wave-free ratio values measured during a ViV simulation session, the procedure was performed safely in the patient the day afterward, without coronary artery issues and with good hemodynamic results. (Level of Difficulty: Advanced.).

SELECTION OF CITATIONS
SEARCH DETAIL
...